KAiWEETS HT118E 20,000 Count Multi-meter
KWET-HT118E Multimeter R 960.00 ex VAT
The new KAiWEETS HT118E is a low-cost, high-resolution, True RMS, multimeter for accurate measurements. Please remember to
use Personal Protection Equipment (PPE) when testing systems with dangerously high voltages. You can click on the images
to see high resolution versions.
Features
- 20,000 Counts (4½ digits) e.g. 19.999 V
- Dual, simultaneous readings - e.g. AC voltage and Frequency
- Accurately measures:
- AC / DC Voltage and Current
- Resistance
- Temperature (Thermocouple included)
- Capacitance
- Frequency
- Duty Cycle
- Diodes
- Continuity
- NCV with Sound and Light Alarm
- Built-in antenna for contactless detection of AC signals (mains)
- Single Probe AC mains live detection
- Backlit Display changes colour when high voltage or current is being tested
- Built-in Flashlight allows testing in dimly lit places
- Sockets light up to indicate Correct Lead Position for Range Selected
- Min / Max to record signal fluctuations
- Stable Kickstand
- Low Battery Prompt
- Data Retention
- Rear probe holders
- Auto Power-off
- Silicon protective surround
- IEC Rated CAT III 1000V, CAT IV 600V, CE, RoHS certified
- Anti-Burn with double ceramic fuse and thermistor protection circuit
- High Voltage Protection is active on all ranges
- Double Insulated
- Includes:
- 2 Probes with shrouded 4mm Probe Connectors
- Thermocouple
- User Manual
- 2x AA Batteries
- Durable EVA Bag with zip (Pouch)
Specifications
General Specifications
Display Measurements |
20000 counts, True RMS |
Safety / Compliance |
CAT III 1,000 V; CAT IV 600 V |
Maximum Voltage |
DC 1,000 V / AC 750 V |
Fuse protection |
μA / mA: F200mA / 250V Fuse |
1O A: F1OA / 250V fuse |
Measurement Speed |
3 times per second |
Range |
Auto |
Battery |
2 x 1.5 V AA Batteries |
Temperature & Humidity |
Operating: 0°C ~ 40°C, < 80% RH, < 10-C non-condensing |
Storage:-10~60 °C, < 70% RH, batteries removed |
Accuracy, Range and Resolution Specifications
Reference condition: environment temperature 18°C to 28°C, relative humidity not above 80%.
Accuracy: ± (% reading + digit increments).
DC and AC Voltage
Voltage |
Range |
Resolution |
Accuracy |
Input Impedance |
Max Input Voltage |
DC Voltage |
200 mV | 10 μV |
±(0.08%+5) |
10MΩ |
1,000 V DC |
2 V | 100 μV |
20 V | 1 mV |
200 V | 10 mV |
1000 V | 100 mV |
AC Voltage |
200 mV | 10 μV |
±(0.05%+25) |
10MΩ |
750 V AC |
2 V | 100 μV |
20 V | 1 mV |
200 V | 10 mV |
1000 V | 100 mV |
Frequency Response: 40Hz - 1kHz True RMS |
DC and AC Current
Current |
Range |
Resolution |
Accuracy |
Overload Protection |
Max Input Current |
DC Current |
200 μA | 10 pA |
±(0.5%+5) |
μA / mA: F200mA / 250 V fuse |
200 mA |
2 mA | 100 pA |
20 mA | 1 μA |
200 mA | 10 μA |
10 A | 1 mA |
±(0.8%+15) | 10A: F10A / 250 V fuse | 10 A |
AC Current |
200 μA | 10 pA |
±(0.8%+5) |
μA / mA: F200mA/250 V fuse |
200 mA |
2 mA | 100 pA |
20 mA | 1 μA |
200 mA | 10 μA |
10 A | 1 mA |
±(1.0%+25) | 10A: F10A / 250 V fuse | 10 A |
Frequency Response: 40Hz - 1kHz True RMS |
Note: When measuring more than 1 A, the measurement time may not exceed 30 seconds |
Resistance and Capacitance
|
Range |
Resolution |
Accuracy |
Overload Protection |
Resistance |
200 Ω | 10 mΩ |
±(1.0%+15) |
250 V |
2 kΩ | 100 mΩ |
20kΩ | 1 Ω |
200 kΩ | 10Ω |
2 MΩ | 100 Ω |
20 MΩ | 1 kΩ |
100 MΩ | 10 kΩ | ±(3.0%+25) |
Capacitance |
2 nF | 100 fF |
±(4.0%+50) |
20 nF | 1 pF |
200 nF | 10 pF |
2 μF | 100 pF |
20 μF | 1 nF |
200 μF | 10 nF |
2 mF | 100 nF |
20 mF | 1 μF |
Frequency and Duty
|
Range |
Resolution |
Accuracy |
Voltage Sensitivity |
Overload Protection |
Minimum Frequency |
Frequency |
200Hz | 10 mHz |
±(1.0%+30) |
100 mV RMS |
250 V |
5 Hz |
2kHz | 10 mHz |
20kHz | 10 mHz |
200kHz | 10 mHz |
2MHz | 10 mHz | 800 mV RMS |
10MHz | 10 mHz | ±(3.0%+30) |
Duty |
1%~99% |
0.1% |
±(3.0%+30) |
|
Temperature
Temperature |
Range |
Resolution |
Accuracy |
°C |
-40 °C - 0 °C |
0.1 °C |
±3 °C |
0 °C - 400 °C |
±(1.0%+2°C) |
400 °C - 1,000 °C |
±2.0 °C) |
°F |
-40 °F - 32 °F |
1 °F |
±6.0 °F) |
32 °F - 752 °F |
±(1.0%+4°F) |
752 °F - 1,872 °F |
±2.0% |
Package List
1 x HT118E Digital Multimeter
2 x Test Leads
1 x User Manual
1 x Thermocouple
2 x AAA Batteries
1 x Durable EVA Bag (Pouch)